Application:Temperature and Water Level Sensor

Product Description

Product Catalogues

Product Videos

The capacitive water level sensor continuously measures free water level below the oil surface and provides an input for on-line net inventory calculations. The integrated multiple spot temperature sensor is Rosemount 565.

The 765 sensor is available in two versions, open and closed. The open version is suitable for crude oil applications and the closed version is suitable for lighter fuels such as diesel oil etc.

One of the Pt-100 temperature sensors can be installed inside the water level probe allowing temperature measurements at low levels.

The water level sensor delivers a high-speed digital signal, which is connected to the Rosemount 2240S Multi-input Temperature Transmitter.

Rosemount 765 is delivered in a stainless steel (AISI 316) housing, welded to the flexible temperature sensor tube to get a hermetic design. It has a heavy duty design with no moving parts.

Offset calibration can be done with an integrated calibration feature in the 2240S transmitter.


Features & Benefits
Measures interface between water and oil
Special crude oil verison is available
Integrated with multiple spot temperature sensor or stand-alone for maximum flexibility
Handles close to bottom measurements
Highest reliability and custody transfer accuracy
Rugged design for harsh environments



Specifications
Technical Data Water Level Sensor

For complete data see Rosemount 565/566/765 Multiple Spot Temperature and Water Level Sensor Product Data Sheet.

Open model:
Suitable for crude oil applications
Closed model:
Suitable for lighter fuels such as diesel oil
Active measuring range:
500 mm (20 in.) or 1000 mm (40 in.)
Output:
High-speed RS485/Modbus communication with Rosemount 2240S
Accuracy:
± 2 mm (0.08 in.) for 500 mm active length
± 4 mm (0.16 in.) for 1000 mm active length
Repeatability:
± 0.5 mm (0.02 in.)
Operating temperature:
0 to 120 °C (32 to 250 °F). Maximum temperature at flange is 80 °C
( 180 °F)
Operating pressure:
0-4 Bar (0-58 Psi). Designed for atmospheric non-pressurized tanks. Handles liquid pressure from hydrocarbons and petrochemical products equivalent to a level of 40 m (130 ft).
Explosion protection:
ATEX, IECEx, FM-US, and FM-C
Mechanical dimensions:
Connection thread: M33x1.5 mm
Length: Active length 140 mm (5.5 in.)
Outer diameter of WLS, closed model: Ø=38 mm (1.5 in.)
Outer diameter of WLS, open model: Ø=48 mm (1.9 in.)
Immersed material:
AISI 316, FEP, PTFE and PEEK with 30% glass
  • 00813-0100-5565.pdf
    1834 KB
    United States
  • api2350_flyer_100519en_revaa.pdf
    1515 KB
    United States
  • 00813-0100-5100.pdf
    17604 KB
    United States
  • 00803-0200-5100.pdf
    1722 KB
    United States
  • 00803-0100-5200.pdf
    2089 KB
    United States
  • 00803-0100-5100.pdf
    8052 KB
    United States
  • 00806-0100-5100.pdf
    2959 KB
    United States
  • 00807-0300-5100.pdf
    3240 KB
    United States
All Products
Other
Log in
New to GM industry Sign up
By signing up,you agree to our terms of use, privacy policy,and cookie policy
have an account? Log in
World Valve Expo Online